1-877-TEMP-AIR
  (877-836-7247)

Air-Cooled After-Coolers
The RECO Air-Cooled After-Coolers are complete systems built to oil-field standards and specifications.

  • Reduces pressure dew point 5-15 F above ambient temperature
  • Removes up to 90% of available moisture
  • Pressures to 400 PSIG
  • Maximum working pressure of 400 psig
  • Electric drive with automatic motor interconnect system - simplifies and selects voltage connection of motor automatically
  • Suitable for outdoor installation

CAPACITY SELECTION CHART Max. scfm @ 5, 10, 15 and 20° F approach temperature to ambient.

Inlet Temp. °F
150
200
250
Approach Temp. °F
5
10
15
20
5
10
15
20
5
10
15
20
RACE-1000
680
1000
1250
1360
520
920
1020
1200
450
810
1000
1000
RACE - 1600 & RACA-1600
790
1440
1950
2260
710
1290
1720
1950
660
1200
1600
1600
RACE - 3500 & RACA-3500
1680
3064
4140
4800
1530
2785
3760
4320
1460
2660
3500
3500

 

ELECTRICALLY DRIVEN
Model
Fan
(cfm)
Motor H.P.
(tefc)
Voltage
Phase
Full Load Amps
Inlet
Outlet
Dimensions (inches)
Weight
H
W
D
RACE-1000
4700
1.5
110/230
1
19/8.6
3"NPT
60
66
36
800
RACE-1600
9700
5.0
208-230/460
3
13 4/7
3"NPT
51
66
36
1000
RACE-3500
17500
10.0
230/460
3
25/13
4"NPT
62
90
60
1500

All motors shown are TEFC, published electrical ratings are approximate, and may vary because of motor brand. Actual ratings are on motor nameplate. Fan motors must not be cycled.

AIR DRIVEN
Model
Fan
(cfm)
Air Motor Usage
Inlet
Outlet
Dimensions (inches)
Weight
H
W
D
RACA-1600
9700
100 scfm
3"NPT
51
66
30
1000
RACA-3500
17500
270 scfm
4"NPT
68
90
60
1500

Consult factory for high pressure or other performance requirements.