Air-Cooled
After-Coolers
The RECO Air-Cooled After-Coolers are complete systems built to
oil-field standards and specifications.
- Reduces
pressure dew point 5-15 F above ambient temperature
- Removes
up to 90% of available moisture
- Pressures
to 400 PSIG
- Maximum
working pressure of 400 psig
- Electric
drive with automatic motor interconnect system - simplifies
and selects voltage connection of motor automatically
- Suitable
for outdoor installation
CAPACITY
SELECTION CHART Max. scfm @ 5, 10, 15 and 20° F approach
temperature to ambient.
|
Inlet
Temp. °F
|
150
|
200
|
250
|
|
Approach
Temp. °F
|
5
|
10
|
15
|
20
|
5
|
10
|
15
|
20
|
5
|
10
|
15
|
20
|
|
RACE-1000
|
680
|
1000
|
1250
|
1360
|
520
|
920
|
1020
|
1200
|
450
|
810
|
1000
|
1000
|
|
RACE
- 1600 & RACA-1600
|
790
|
1440
|
1950
|
2260
|
710
|
1290
|
1720
|
1950
|
660
|
1200
|
1600
|
1600
|
|
RACE
- 3500 & RACA-3500
|
1680
|
3064
|
4140
|
4800
|
1530
|
2785
|
3760
|
4320
|
1460
|
2660
|
3500
|
3500
|
| ELECTRICALLY
DRIVEN |
|
Model
|
Fan
(cfm)
|
Motor
H.P.
(tefc)
|
Voltage
|
Phase
|
Full
Load Amps
|
Inlet
Outlet
|
Dimensions
(inches)
|
Weight
|
|
H
|
W
|
D
|
|
RACE-1000
|
4700
|
1.5
|
110/230
|
1
|
19/8.6
|
3"NPT
|
60
|
66
|
36
|
800
|
|
RACE-1600
|
9700
|
5.0
|
208-230/460
|
3
|
13
4/7
|
3"NPT
|
51
|
66
|
36
|
1000
|
|
RACE-3500
|
17500
|
10.0
|
230/460
|
3
|
25/13
|
4"NPT
|
62
|
90
|
60
|
1500
|
All
motors shown are TEFC, published electrical ratings are approximate,
and may vary because of motor brand. Actual ratings are on motor
nameplate. Fan motors must not be cycled.
|
AIR
DRIVEN
|
|
Model
|
Fan
(cfm)
|
Air
Motor Usage
|
Inlet
Outlet
|
Dimensions
(inches)
|
Weight
|
|
H
|
W
|
D
|
|
RACA-1600
|
9700
|
100
scfm
|
3"NPT
|
51
|
66
|
30
|
1000
|
|
RACA-3500
|
17500
|
270
scfm
|
4"NPT
|
68
|
90
|
60
|
1500
|
Consult
factory for high pressure or other performance requirements.
Contact